Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Linking a create imposition to an output from imposition hot folder causes failure


Product

 

Prinergy Evo 1.2


Error

 

The process cannot find pages that are referenced by the imposition JDF.


Symptoms

 

The process fails if you use a hot folder that is linked to a create imposition process template followed by an output from imposition hot folder.


Cause

 

The create imposition process creates a JDF file from a run list of PDF files. In the Input Files Relocation area of the create imposition process template, you can control whether Prinergy Evo copies or moves the PDF files. An error occurs if you copy or move the PDF files to an output from imposition hot folder. This type of hot folder does not accept PDF files and relocates them to its Input_Error folder. The output from imposition process will fail to find the PDF files in the Input_Error folder.


Solution

 

Set a different location for the PDF files so they are located outside of the hot folders or ensure that the create imposition process template leaves the PDF files in their original location.


Technical contact(s)
 

Josh Garrett

Submitted by
 

Josh Garrett

Date submitted
 

5 April 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.