Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Calibration curves are missing after restarting Prinergy Evo


Product

  Kodak Prinergy Evo 3.0.6.x

Error

 

Output fails due to missing calibration curve.


Symptoms

 

The calibration curve cannot be found during output and the output process fails. Alternatively, calibration curves cannot be selected in the Process Template Settings dialog box when you want to use dynamic settings.


Cause

 

In Prinergy Evo 3.0.6.x, if you restart the Prinergy Evo Server software by clicking Restart, the calibration curves may not appear in the Process Template Editor or in the Process Template Settings dialog box.


Solution

 

Perform one the following workarounds:

  • Use the Stop and Start buttons in the Prinergy Evo Server software.
  • Click Restart and start the Kodak Harmony tonal calibration software to refresh the curves.

This issue is fixed in Prinergy Evo 3.1.6.x.


Technical contact(s)
 

Josh Garrett

Submitted by
 

Josh Garrett

Date submitted
 

23 August 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.