Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Prinergy Evo cannot start or stop due to Copydot JTP Failure


Product

 

All versions of Kodak® Prinergy® Evo™ software

 

 
Error  

CopydotJTP.exe experiences a runtime error.


Symptoms

 

The system stops unexpectedly or is unable to start with an error related to CopydotJTP.exe.


Cause

 

Having four or more Kodak Copydot job ticket processors (JTPs) on some systems can cause the fourth JTP to fail to start. Investigation into this problem is ongoing.


Solution

 

The following procedure can be used to reduce the number of Copydot JTPs that Prinergy Evo starts.

  1. Using Microsoft® Windows® Explorer, locate the following file on the Prinergy Evo server computer:

    <hard drive> \Program Files\Kodak\Prinergy Evo <version>\config_data\System\NodeManager-Local\config.txt

  2. Using Notepad, type this line at the bottom of the file:

    Jasper.DMGR.daemons.Copydot.Instances=1

  3. Save the file.


  4. Restart the Prinergy Evo Server software.

Technical contact(s)
 

Josh Garrett

Submitted by
 

Josh Garrett

Date submitted
 

4 April 2007


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.