Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
All versions of Kodak® Prinergy® Evo | ||
Error |
The Prinergy Evo Client software displays, | ||
Symptoms |
When starting the Prinergy Evo Client software on the server computer, the Connect to a Prinergy Evo Server dialog box displays no servers or the local server is not listed, even though the Prinergy Evo Administrator is started and is running. |
||
Cause |
One of the network cards on the Prinergy Evo server computer is either disconnected or has limited connectivity. This can occur with Gigabit Master Control Electronics (GMCE) devices when the device is turned off, or on dual network card systems where the site is only using one network card. |
||
Solution |
Make sure that the second network card is properly connected to a network, or disable it if it is disconnected or if it is not going to be used. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
10 May 2007 |
||