Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Prinergy Evo Client software does not show a server IP address on computers with more than one network card


Product

  All versions of Kodak® Prinergy® Evo™

Error

 

The Prinergy Evo Client software displays, The server is not available or not responding. Alternatively, the software shows that no servers are available on the network, even though the Prinergy Evo Administrator is started and is running.


Symptoms

 

When starting the Prinergy Evo Client software on the server computer, the Connect to a Prinergy Evo Server dialog box displays no servers or the local server is not listed, even though the Prinergy Evo Administrator is started and is running.


Cause

 

One of the network cards on the Prinergy Evo server computer is either disconnected or has limited connectivity. This can occur with Gigabit Master Control Electronics (GMCE) devices when the device is turned off, or on dual network card systems where the site is only using one network card.


Solution

 

Make sure that the second network card is properly connected to a network, or disable it if it is disconnected or if it is not going to be used.


Technical contact(s)
 

Josh Garrett

Submitted by
 

Josh Garrett

Date submitted
 

10 May 2007


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.