In the application event log, you will see the following two events:
|
||
Symptoms |
The rendering processing engine executable, CSWRendProcessing.exe, won’t start up successfully. The controller that starts it waits 20 seconds for the executable to start successfully, and when it has not started up in that time, it quits the executable and starts another one, so the CSWRendProcessing.exe executable never starts. You can see this happening in the log file CSWDiagnostics.log. If you manually start the process from a command line, the process does eventually start, but takes longer than the allowed 20 seconds. Because no rendering engine starts successfully, no thumbnails are generated and elements cannot be viewed in Smart Review. This problem typically appears on a freshly ghosted system. |
||
Cause |
Part of the installation procedure when installing a server baseline ghost is to disable and then manaually re-enable the Appletalk protocol. If this is not performed, you may get the problem as specified above. The problem seems to be more common on Dell® PE2900 servers than PE2800 servers. |
||
Solution |
Disable and then re-enable the Appletalk protocol by completing the following steps:
|
||
Technical contact |
|||
Submitted by |
|||
Date submitted |
29 Sep 2006 |
||