14 Jun 2004: Downgrading the Thermal 1.x Head Firmware or LCA Bundle May Cause Errors More...
There has been a re-design of the TH1.x Light Valve Driver (LVD) board. Testing shows that the new board functions identically to the old boards, and the change should be largely invisible. Unfortunately, the new board does not support all versions of head firmware, or of the head LCA bundle. To function properly, the head must be running firmware V1.93 or higher, and it must have the LCA bundle lcav503.hex installed (lcav105.hex, lcav103.hex, and older bundles will not function). If you receive a head with the new board, you must not downgrade the firmware or LCA bundle.
If you downgrade to firmware V1.83 or older on a head with the new board, problems may include:
If you load LCA bundle lcav105.hex or older on the head, you will see the error message:
LV LCA not initialized
In both cases, the solution is to upgrade to head firmware V1.93+ and lcav503.hex. For instructions on loading firmware, or for firmware versions, see below.
To determine if your head has the new board, type head version and look for LVD hardware version:. The new LVD board will be version 2 or version 6.
| Version | Status | Part # / ECO | Date | Notes |
| 2.01 | Controlled release | 636-00170A |
Mar 2007 |
Only install this firmware on output devices that support version 2.01. New features in version 2.01 are:
For full details see Thermal 1.X Head Firmware Version 2.01 Release Notes |
| 2.00 | Controlled release | 636-00154A |
Aug 2006 |
The changes from version 1.97 are:
Installing head firmware version 2.00 requires ServiceShell. Thermal 1.X Head Firmware Version 2.00 Release Notes To upgrade to Thermal 1.x Head firmware version 2.00, you must use FirmwareUpgrade.spt script version 4.94 or greater.
Note: The script files are bundled with the TH1.x V2.00 firmware. These files have been tested on Service Shell 2.5 Service Pack 2, Service Shell 2.6 Service Pack 2, Service Shell 3.0, and Service Shell 3.1. |
| 1.97 | Controlled release | 636-00131A-A,br> CA06107 |
Dec 2004 |
Only install this firmware on output devices that support version 1.97. Version 1.97 corrects stroke corruption that may occur with versions 1.93 and 1.95. Installing head firmware version 1.97 requires ServiceShell. |
| 1.95 | Controlled release | 636-00076A-A |
Jun 2004 |
WARNING:There is a bug in V1.95 that impacts all devices. Any sites with V1.95 should be upgraded to V1.97 as soon as it becomes available. |
| 1.93 | Controlled release | 636-00056A-A |
Feb 2004 |
WARNING: There is a bug in V1.93 that impacts all devices. Any sites with V1.93 should be upgraded to V1.97 as soon as it becomes available. |
| 1.92 | Controlled release | 636-00055A-A |
Dec 2003 |
WARNING: There is a bug in V1.92
that impacts MCE devices. This firmware should not be loaded at new
sites. On MCE devices, you will be unable to access or change the
active |
| 1.83 | Controlled release | 636-00003A-A |
Jan 2003 |
Only install this firmware on output devices that support version 1.83. Version 1.83 supports P33 imaging, and corrects bugs in V1.80 and V1.82. Installing head firmware version 1.83 requires ServiceShell. |