Error Message: |
ALE: no plate detected on unload vacuum cups |
Applies to: |
|
Service Information: |
Use verbose 1 to get progress & debugging information. Check the suction cups, see the procedure for setting uvt & pvt 3230/3244 Trendsetter Autoloader: During an unload, this error is reported if the vacuum measured on the unload cups is not above the "al uvt" threshold after a time of "aldly vac" after the cups are moved up. Check the vacuum level with the "table" command. If it is okay, check the "aldly vac" delay. If the vacuum reads low but the plate is held firmly, check the "set sat aoff 5" parameter - it should be around 0. Platesetter_3244: Use alcmd verbose 2 and all verbose 1 to get progress & debugging information. Check the suction cups, see the procedure for setting uvt & pvt During an unload, this error is reported if the vacuum measured on the unload cups is not above the "al uvt" threshold after a time of "aldly uvac" after the cups are moved up. Check the vacuum level with the "uvac" command. If it is okay, check the "aldly uvac" delay. If the vacuum reads low but the plate is held firmly, check the "set sat aoff 5" parameter - it should be around 0. |
Operator Action: |
Select Resume if that option is available. If this error persists, call Creo Response Center. |