Error Message: |
ALE: plate picker vacuum did not release in time, check air lines |
Applies to: |
|
Service Information: |
Check if plate was really released. Check for oil in air lines and any other possible cause for air valve to be sticking. Perform Cal pvac (& cal uvac). NOTE: Vacuum thresholds are very sensitive to ambient temperature. Replace PPE board (or U15 ACD0838) if problem persists. aldly release may be increased to 1.5 seconds but this will directly affect the load/unload time. |
Operator Action: |
Resume. Inform Creo response center so that the problem can be checked at next p.m. inspection. If problem persists, call Creo service. |
Cause:
|
See Also: |
|