Error Message: |
ALE: Picker timed out moving [up!down!out] |
Applies to: |
|
Operator Action: |
Select the RESUME button on the workstation dialog box. If this fails to correct the problem, open the plate cover and inspect the picker head. The picker should be in the position specified by the error messsage (i.e. up, down, or out) and the magnetic reed switches should be tripped. If everything looks normal, then Creo Service should be called. The picker "in" position is towards the plate stack. |
Service Information: |
At least one of the magnetic reed switches for the picker head failed to trip within the timeouts specified by the aldly pio or aldly pud parameters. The sensor status may be checked by using the PICKER command. The sensor status should read TRUE if the sensor is activated. The sensors are wired in series, so both of them need to be tripped for the status to read TRUE. There are no sensors for the picker "in" (toward the plate stack) position. The firmware uses the full delay specified by aldly pio when waiting for the picker to move in. It may be useful to set the 'verbose alcmd' parameter to 1 in order to obtain further diagnostic information. Typing "ALE" will display the system air pressure. |
Cause:
|
See Also: |