Error Message: |
ALE: Please put plate cover in manual bypass position |
Applies to: |
|
Operator Action: |
Open the plate cover and put it into the manual bypass position. Select the RESUME button on the workstation dialog box. If the problem persists, then Creo Service should be called. |
Service Information: |
Either the plate cover door is closed or there is a problem with the sensor. This error is reported if the plate over door is closed when the system is preparing to manually unload a plate up the front of the machine. The sensor status may be checked by using the PICKER command. The sensor status should read TRUE if the plate cover sensor is activated and the plate cover is closed. Opening the cover or putting it into manual bypass position should cause the sensor to read FALSE. It may be useful to set the 'verbose alcmd' parameter to 1 in order to obtain further diagnostic information. |
Cause:
|
See Also: |
Go to CTP Firmware Error Index Page
Go to CTP Firmware Error Search Page