Error Number: 15393


Error Message:

ALE: Invalid or mis-loaded carrier (optical).

Expecting <proof-type name> carrier.

Click RESUME and wait 1 min before reload.


Applies to:

  • Trendsetter_400/800_Proofing

Operator Action:

The expected carrier ID was not verified. The most likely causes are that the incorrect carrier was loaded or the correct carrier was mis-loaded. Select RESUME from the workstation dialog box, verify that you have the correct carrier for the specified proof format and try to reload it. Please note that after RESUME or CANCEL IMAGE is selected, it may take up to 60 seconds for the invalid carrier to be ejected from the machine. When the invalid carrier is ejected, the workstation will prompt for removing the carrier. If problem persists call Creo service.


Service Information:

The expected carrier ID was not verified. The most likely cause is that the incorrect carrier was loaded or the correct carrier was mis-loaded. Click RESUME from teh workstation dialog box, verify that you have the correct carrier for the specified proof format and try to reload it. If problem persists see other causes mentioned below.


Cause:

  • User loaded wrong-sized or invalid carrier.
  • Proof "hpos" parameter not set to factory settings.
  • Carriage "cph" parameter not being set up properly.
  • Drum "epos" parameter not being set up properly.
  • Edge detect not working properly due to improperly set "head onthresh" and "head offthresh" parameters.
  • A damaged or dirty edge detect strip.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:42 2002 PST