Error Message: |
HEAD: multiple edges detected - verify image position |
Applies to: |
|
Service Information: |
This is not an error - it is an informational message only. While searching for the edge of the plate, the head "saw" two edges. The "media x edge" parameter was set to 2, so this condition is allowed, and the first edge is taken as the true edge. Each time this occurs, the "state imaging double_edge_count" is incremented, and this warning message is sent to the workstation. The total count can be checked with the "list stats" command. |
Operator Action: |
The edge of the plate was not well defined, so the registration may be inaccurate. Check the image position on the media, and re-run the job if necessary. If this happens frequently, contact the CreoScitex Response Center. |
Cause:
|
See Also: |
|