Error Number: 17502


Error Message:

HEAD: value out of range


Applies to:

  • All

Service Information:

Some value in the head is out of range.

For a thermal head, if this error occurred during a stroke or scorr command, check that the head parameters swidth and soffset sum together to give a value of 240 or less. If not, either pixels need to be chopped or the stroke offset needs to be changed.


Operator Action:

Call service.


Cause:

  • Some value in the head firmware is out of range. This is could be an internal value, an NVS value, or a user-entered value. This error may occur during scorr or stroke commands, when the NVS parameters "head soffset" and "head swidth" sum together to give a value greater than 240.

See Also: