Product |
|
Dolev® 800V+
|
|
Background |
|
This procedure describes how to upgrade Dolev
800V+ with TSP to Dolev 800V2 with TSP.
|
|
Part list |
|
| P/N |
Description |
Qty |
| 282E9L386 |
N/P for Dolev 800V2 |
1 |
| 503C2L088S |
Brushless D800V2 |
1 |
| 510V52149J |
S/W Dolev 800V2 Pack |
1 |
| 374A00080 |
Packing Label-Wht
.749-2T651 |
1 |
|
|
Time required |
|
1 day |
|
Procedure |
|
-
Save parameters to a Software Machine Parameters Dolev 800V2
diskette (501V1M353).
-
Turn off the machine and disconnect the main power cable.
Important: Wear an antistatic cable wrist band while
performing the following steps.
-
Remove the brushless board (503C2L011S) from the standard controller.
-
Install the replacement brushless D800V2 (503C2L088S).
-
Replace the panel N/P with NP for Dolev 800V2 (292E2U386).
-
Cut the black loop wire from the 76-pin cable (P3) to change the
configuration.
-
Connect the main power cable and turn on the machine.
-
Reboot the imagesetter with the Micro Version diskette (version 1.034).
-
Reboot the imagesetter with the diagnostic diskette (ver 2.68 August
2000).
-
Remove the diagnostic diskette, and then reboot the imagesetter.
-
Reset the parameters (Tools>Setup>Set default params>Set default values).
-
Restore the parameters from the Software Machine Parameters Dolev 800V2
diskette.
-
Remove the diskette from the floppy drive.
|
|
Test |
|
Testing and calibrating
-
Insert the Resintensity value for all resolutions,
and then calibrate
the imagesetter.
-
Check that the imagesetter registration is according to the
specification. If required,
calibrate with the grid measurement kit.
Test
Run an ATP or a customer job and check that the imagesetter is according
to the Dolev800 V2 specification. (See the Dolev800 V2 User Manual.)
|
|
Material
Disposition |
|
Send all the parts that you removed to Creo
CIL.
|
|
Technical contact(s) |
|
Content owner: Oded
Zaccai
See the Escalation page for
escalation contacts.
|
Date submitted |
|
28 Oct 2002 |