Dolev 800/800V/800VČ - Brisque Application Issues
Diskette Drive Operation
A 3.5 inch floppy diskette drive is located in front of and below the panel. The floppy diskette is inserted in the disk drive before the imagesetter is powered on. The floppy loads all of the information the imagesetter needs for normal operations. Do not remove the diskette from the machine unless instructed by your supplier.
The panel is designed to work in two modes, Exposure Mode or Diagnostics Mode.
| Exposure Mode: | Set Loading assists you during
the loading process. During the loading process, the section of media exposed to light
during loading must be cut. Set Loading automatically cuts the exposed media and disposes
of it in the output cassette. For this reason, be sure that the output cassette is empty
before you load a new supply cassette onto the imagesetter. During an exposure, the control panel displays the percentage of the exposure completed. The operator uses the panel in two cases. The first case is when changing media types. The operator updates the imagesetter with the new media information. |
| Diagnostics Mode: | The second case is
when there is a machine failure. The operator has the option of calling
CreoScitex Service, or using the Diagnostics diskette. a) Press F1 (UTIL) on the control panel. b) Select Diagnostics. Insert the 3.5 inch floppy diskette into the drive and run the diagnostics. The diagnostics help isolate the problem. Depending on the nature of the problem, you either perform the troubleshooting or consult the CreoScitex Service Engineer. |