Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Dolev 800
Prepared By: A. Posner
March 9, 1994
Parts Affected : 507C38076
The 90 deg. elbow and its T-fitting are replaced together with the punch cover to improve Slugs Removal in cases where a slugs removal problem exists.
Explanation of Conditional Change :
Implement this FCO in cases that slugs removal problems exists.
FCO Kit part no. : 510F18908
Effectivite on all Punch basket big-R
Note: Punch Big considered as punch where the hole is bigger than 3/8" in one direction.
Reason for Change
Description of Change
Change Procedure
Test Procedure
Parts List
Attached Documentation
Material Disposition
Logistics
In order to improve the slugs removal. In cases where a problem exists, more space is needed inside the slugs compartment in the punch unit and inside the 90 deg. elbow.
The 90 deg. elbow and its T-fitting are replaced together with the punch cover.
Note: This procedure should be performed on an uninstalled punch unit. Before removing the punch unit mark the position of the unit in order to install it back in the correct place.
| 290A38968 290A38973 290B36237 |
ELBOW - 90 DEG. D=22 x 1 UNION T D=22 x 1 COVER - BIG x 1 |
Attached drawing
Can be disposed.
Material for performing this FCO will be shipped as of 1.5.94 according to orders from the subsidiaries.