Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Dolev 800

Prepared By: A. Posner
March 9, 1994

FCO 18908 - Dolev 800 Punch Basket Big R

Parts Affected : 507C38076

The 90 deg. elbow and its T-fitting are replaced together with the punch cover to improve Slugs Removal in cases where a slugs removal problem exists.

Explanation of Conditional Change :

Implement this FCO in cases that slugs removal problems exists.

FCO Kit part no. : 510F18908

Effectivite on all Punch basket big-R

Note: Punch Big considered as punch where the hole is bigger than 3/8" in one direction.

Reason for Change
Description of Change
Change Procedure
Test Procedure
Parts List
Attached Documentation
Material Disposition
Logistics

Reason for Change

In order to improve the slugs removal. In cases where a problem exists, more space is needed inside the slugs compartment in the punch unit and inside the 90 deg. elbow.

Description of Change

The 90 deg. elbow and its T-fitting are replaced together with the punch cover.

Change Procedure

Note: This procedure should be performed on an uninstalled punch unit. Before removing the punch unit mark the position of the unit in order to install it back in the correct place.

  1. Remove the punch unit from the plotter (it is strongly recommeded to check it before installing the unit).
  2. Release the two screws (#22).
  3. Remove the punch cover (#24).
  4. Move the two sping washers (#7) from the screws to the inside part of the cover between the cover and the punch block.
  5. Reinstall the new cover (cat. no. 290B36237).
  6. The modified unit can be installed.
  7. Install the modified unit using the new T union (290A38973) and the new 90 deg. elbow (290A38968).
  8. After installation perform several sequences and make sure that the slugs are properly removed.
  9. Make sure that the Punch unit is in the correct position according to the customer ruler.

Test Procedure

  1. Perform several punch sequences and make sure that the slugs are properly removed.
  2. Check all the punches location according to the customer ruler.

Parts List

290A38968
290A38973
290B36237
ELBOW - 90 DEG. D=22 x 1
UNION T D=22    x 1
COVER - BIG     x 1

Attached Documentation

Attached drawing

Material Disposition

Can be disposed.

Logistics

Material for performing this FCO will be shipped as of 1.5.94 according to orders from the subsidiaries.


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.