Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Prepared By: A. Posner
March 20, 1993
Parts Affected: 506E32052
In cases that the Spinner Driver Board goes into a shutdown mode or cause fails in start up, replace the Spinner Driver Board comp. level N with board having Comp Level O.
Explanation
of Conditional Change
Reason for Change
Description of Change
Change Procedure
Test Procedure
Parts List
Material Disposition
Logistics
Implement this FCO in cases that the Spinner Driver Board goes into a shutdown mode or cause fails in start up. The relevant error messages are detailed in paragraph 1.
Change compatibility level from N to O.
The Spinner Driver Board changes its mode to shutdown on some power levels. This is due to sensitivity to noise of one of the components on the board. Sometimes the board will cause failures at power on.
The relevant error messages are:
CRI Index Freq. error
Spinner enc. freq. err
OMC spinner frequency Error
spinner set error
And the spinner will not rotate (red led will be lit).
Replacing the Spinner Driver Board comp. level N with board having comp. level O.
Make sure that the self test passes without any error message.
Turn on the spinner in the diagnostics and make sure it rotates.
The kit for performing this FCO consists of:
| 503C27381 | SPINNER DRIVER BOARD (COMP. LEVEL O) | x 1 |
The replaced Spinner Driver Board should be sent back to STCL for update.
The material for performing this FCO will be shipped according to orders from the subsidiaries.