Prepared By:    A. Posner

FCO 19100 - CRI Board - Solving White Stripes

Parts Affected 503D29069

Replacing CRI Board with Level N to solve white stripes (larger than 50 micron) appearing at "stop spiral".
               
Explanation of Conditional Change
Reason for Change
Description of Change
Change Procedure
Test Procedure
Parts List
Material Disposition        
Logistics

Explanation of Conditional Change

This FCO should be implemented in casaes when white stripes appear (larger than 50 micron) at "stop spiral".

Change compatibility level from M to N.   

Reason for Change

Sometimes during stop spiral, white stripes (larger than 50 microns) appear. The change will eliminate this problem.       

Description of Change

The CRI board Comp. level M is replaced with CRI board Comp. level N.

Change Procedure

  1. Power off the Dolev 800.                    
  2. Pull out the CRI board from the Standard controller.        
  3. Insert the new CRI board that was supplied in the FCO kit (with Comp. level N).                        
  4. Restore power.   

Test Procedure

Switch the Dolev 800 between "ON" and "OFF" and make sure that "standby" appears without an error message.

Parts List

The kit for performing this FCO consists of:

503D29069 CRI BOARD ASSY (Comp. level N) x 1

Material Disposition        

The replaced board should be sent back to STIL for update.

Logistics

Material for performing this FCO will be available as of July 15th 94 and will be shipped according to orders from the subsidiaries.   