Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
May 23, 1994
Prepared By: A. Posner
Parts Affected 503D29069
Replacing CRI Board with Level N to solve white stripes
(larger than 50 micron) appearing at "stop spiral".
Explanation of
Conditional Change
Reason for Change
Description of Change
Change Procedure
Test Procedure
Parts List
Material Disposition
Logistics
This FCO should be implemented in casaes when white stripes appear (larger than 50 micron) at "stop spiral".
Change compatibility level from M to N.
Sometimes during stop spiral, white stripes (larger than 50 microns) appear. The change will eliminate this problem.
The CRI board Comp. level M is replaced with CRI board Comp. level N.
Switch the Dolev 800 between "ON" and "OFF" and make sure that "standby" appears without an error message.
The kit for performing this FCO consists of:
| 503D29069 | CRI BOARD ASSY (Comp. level N) | x 1 |
The replaced board should be sent back to STIL for update.
Material for performing this FCO will be available as of July 15th 94 and will be shipped according to orders from the subsidiaries.