June 26, 1994

FCO #19290 Adding Electrostatic Discharge Brushes to the Film Path - Dolev 800/800P

Add Electrostatic Discharge Brushes to the Film Path in cases where static electricity is causing problems.

Explanation of Conditional Change
Reason for Change
Description of Change
Change Procedure
Test Procedure
Parts List
Logistics

Explanation of Conditional Change

Implement this FCO in cases where the electrostatic discharge is needed in the film path.

FCO Kit part no. : 510F19290
Effective on machines with S/N lower then 9430XXXX

Reason for Change

Sometimes electrostatic discharge is needed in the film path. The film is attached to the drum during loading and that can cause registration problems.  The film can get stuck during unload due to the electrostatic.

Description of Change

Electrostatic discharge brushes have been added in four places in the loading and unloading path.   

Change Procedure

  1. Turn off the plotter.

  2. Pull out the loading system.

  3. Remove the CLAMP from the loading system by releasing the two shaft clamp housings (4 screws) and the two springs.

  4. Remove the two clamp-CAM from both sides of the clamp.   

  5. File the anodize coating from the clamp in the places where the brush will be glued (10 places 20mm each).           

  6. Attach the brush to the clamp according to the enclosed figure.

  7. Reinstall the two clamp-CAMs.

  8. Cut out the brush from the edges.

  9. Reinstall the clamp assembly.

  10. Remove the unloading film guide from the loading system.

  11. Attach the brush to the guide.

  12. Reinstall the unloading film guide and make sure that the brush is attached to the cutter base.

  13. Cut out the brush from the edges.

  14. Remove the funnel from the plotter.

  15. Attach the brush on the selecting cover and secure it with the caterpillar. Press on the caterpillar in order to secure the brush.

  16. Glue the caterpillar edges using the adhesive rapid cure glue.

  17. Remove the selector film guide base from the funnel.

  18. File the anodize coating from the base in the places where the brush will be glued (10 places 20mm each).

  19. Attach the brush to the base.
  20. Install the selector base and the funnel into the plotter.   

Test Procedure

Load and unload film and make sure that no electrostatic problems appear.                                
In case of film crash ("S" effect) then:

Parts List

The kit for performing this FCO consists of:

401K10011 ANTI STATIC BRUSH ADHESIVE 10 mm x 4 Meter
480C43500 ADHESIVE RAPID CURE 3GR. x 1
203B10240 CATERPILLAR .085 WIDTH x 1 Meter
363B06152 EXTN. SPRING x 2 (as spare)

Logistics

Material for performing this FCO will be available as of 1-SEP-94 and will be shipped to the subsidiaries according to orders.