Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Prepared By: A. Posner
June 26, 1994
Add Electrostatic Discharge Brushes to the Film Path in cases where static electricity is causing problems.
Explanation
of Conditional Change
Reason for Change
Description of Change
Change Procedure
Test Procedure
Parts List
Logistics
Implement this FCO in cases where the electrostatic discharge is needed in the film path.
FCO Kit part no. : 510F19290
Effective on machines with S/N lower then 9430XXXX
Sometimes electrostatic discharge is needed in the film path. The film is attached to the drum during loading and that can cause registration problems. The film can get stuck during unload due to the electrostatic.
Electrostatic discharge brushes have been added in four places in the loading and unloading path.
Load and unload film and make sure that no electrostatic
problems appear.
In case of film crash ("S" effect) then:
The kit for performing this FCO consists of:
| 401K10011 | ANTI STATIC BRUSH ADHESIVE 10 mm | x 4 Meter |
| 480C43500 | ADHESIVE RAPID CURE 3GR. | x 1 |
| 203B10240 | CATERPILLAR .085 WIDTH | x 1 Meter |
| 363B06152 | EXTN. SPRING | x 2 (as spare) |
Material for performing this FCO will be available as of 1-SEP-94 and will be shipped to the subsidiaries according to orders.