Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
a-
Prepared By: B. Peretz
July 21, 1994
Part(s) Affected: 503D29069
This FCO should be implemented in cases where the Stepper signals from the CRI are distorted. In such cases the implementation of the FCO might improve the performances of the stepper.
Explanation
of Conditional Change
Reason for Change
Description of Change
Change Procedure
Test Procedure
Parts List
Logistics
This FCO should be implemented in cases where the Stepper signals from the CRI are distorted. In such cases the implementation of the FCO might improve the performances of the stepper.
FCO Kit part no. : 510F19705
Change compatibility level from N to O
Replace component CR 205 from 130B05600 to 130B04300.
Note: This FCO should be implemented only in cases where the following test will:
If the sine wave appears perfectly okay, then the FCO should not be implemented. If the sine wave is cut in the top of the signal, then the FCO should be implemented.
Repeat the test mentioned in the change procedure section. Verify that stepper sine waves have been improved.
The kit for performing this FCO consists of:
| 130B04300 | DIODE ZENER 0.4W 4.3V | x 1 |
Material for performing this FCO will be shipped according to orders from the subsidiaries.