Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


1b2_0.gif (1329 bytes)Field Change Order

FCO #21881 January 25, 1996

VLSI CLASS II Comp. L

The VLSI Board Cat. Number 503D40259 is replaced with a new board ( Comp. Level L ).

Note: This FCO refers only to the new VLSI Class II Boards Cat #503D40259. The new boards function the same as the old VLSI boards.

Header Info
1. Reason for Change
2. Description of Change
3. Change Procedure
4. Test Procedure
5. Parts List
6. Attached Documentation - None.
7. Material disposition
8. Logistics

Header Info

Prepared By: A. Posner FCO Kit No.: 510F21881
Comp. Level: L Machine S/N: N/A
Catalog No. 503D40259 S/W Affected: N/A
Type of Change: Mandatory
Product Mgr: G. Menchik Approval Date: 01/13/96
Product Support: S. Amit Approval Date: 01/24/96
Service Mgr: S. Cohen Approval Date: 01/25/96

1. Reason for Change

The board ( 503D40259 - VLSI CLASS II ASSY ) cause to communication hang up.

2. Description of Change

Replace the VLSI class ( 503D40259 ) board with board Comp. level L

3. Change Procedure

3.1 Check and configure the board's dip switches as follows:

If installed inside the Whisper:

U311 On: 4,6,7
Off : 1,2,3,5,8
U314 On: none
Off: al

If installed inside the imagesetter:

U311 On: 4,5,6,8
Off: 1,2,3,7
U314 On: 2,3,4,5,6,7,8
Off: 1

Dip Switches with no change:

U1515 (4 DIP-SWITCHs device) : On: 2
Off: 1,3,4
U1308A (4 DIP-SWITCHs device): On: 1
Off: 2,3,4

3.2 Replace the VLSI class board with the one supplied in the FCO kit. 

4. Test Procedure

4.1 Check communication between the Host and the Plotter.    
4.2 Expose and make sure that the problem with the board disappears.

5. Parts List

The kit for performing this FCO consists of:

503D40259    VLSI CLASS II ASSY BOARD x 1 (COMP. LEVEL L)

6. Attached Documentation - None.

 

7. Material disposition

The replaced board should be sent back to STIL for upgrade.   

8. Logistics

Material for this FCO will be supplied two months after an order will be placed.

STA can order up to 5 kits
STE can order up to 5 kits
STMA can order up to 1 kits
STAP can order up to 3 kits
STN can order up to 4 kits.


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.