The Dolev 800 and 800P have undergone many changes recently with many ECO's, FCO's and Diagnostics.
In this FSB we will summerize the changes and the differences in the Dolev plotters.
Dolev 800 is a Dolev with s/n from 11001 to 11095.
Dolev 880P is a Dolev with s/n 11151 and higher.
A new S/N will start with plotter # 11286. See the enclosed explanation.
16104
Panel Kit (Eprom)
FCO type: Conditional
Effective on machines with S/N from 11001 to 11015
Reason for change: The first 15 plotters were supplied with EPROM which contained micro
version 1.0 for the panel. This version was not planned to work with system version 4. The
new EPROM contains panel micro version 1.1 which was programmed to work with system
version 4.
16561
Lables for loading cassettes
FCO type: Mandatory
Effective on machines with S/N up to 11085
Reason for change: Missing film installation procedure.
16669
Interlocks and door lockers
FCO type - Mandatory
Effective on machines with S/N 11001 to 11080
Reason for change: Improving the side doors locking and adding safety interlocks
16671
Fast DATA-I board comp level K to M
FCO type - Conditional
Effective on machines with S/N up to 11085
Reason for change: Modification of the boardto support connection of Fast DATA-II via SFLM
boards.
16850
Strobe-5 board. comp level N to O
FCO type - Conditional
Effective on machines with S/N 11001 to 11085
Reason for change: To prevent PLL locking problems at start of plot by limiting minimum
VCO input voltage to 2V at low range and 4.5V at high range.
16928
Spinner Driver board comp level K to L
FCO type - Mandatory
Effective on machines with S/N 11001 to 11081
Reason for change: The 4A circuit breakers are not suitable to protect the Spinner motor
& the power transformer against overheating.
17090
Shutter protector
FCO type: Conditional
Effective on machines with S/N lower than 11095
Reason for change: The Shutter Protector causes scratches on the film during the loading
process.
16895
Fast DATA-I board comp level L to M
FCO type: Conditional
Effective on machines with S/N up to 11090
Reason for change: Communication problems during working with fiber optic cables via the
SFLM boards.
17248
CRI board comp level L to M
FCO type:
Effective on machines with S/N 11001 to 11070
Reason for change: In order to solve intermittent start up problem appearing with the
message "CRI start up failed".
17401
Fast DATA-II board comp level N to O
FCO type: Conditional
Effective on machines with S/N lower than 11075
Reason for change: Single black points appeared in the center of white dot. These points
were caused by noisy X clock and Y clock signals. The noise was generated by reflection
from incorrect termination of these signals.The change will eliminate the unwanted points.
17409
OMC board comp level O to P
FCO type: Conditional
Effective on machines with S/N lower than 11080
Reason for change:
Solve analog MUX 16 problem
Solve "OMC BAD COMMUNICATION" intermittent.
Solve OMC/ANALOG/MODULATOR failures.
Enable diagnostics from host via signal cable.
17684
Adding Rubber wire to the Spreader
FCO type: Conditional
Effective on machines with S/N:Dolev 800 - all
Dolev 800P - lower than 11260
Reason for change: During loading, the film touches the lead screw which can cause
scratches on the film. Sometimes the film gets wrinkled during loading.
17766
Replacing Sprockets - Scratches
FCO type: Conditional
Effective on machines with S/N lower than 11280
Reason for change: Scratches on film from the Loading system can be eliminated by
replacing the sprocket on the feeder motor and by lowering the loading system by 3mm. The
Unloading film guide should be replaced in order to avoid funnel problems due to 3mm
lowering.
17782
Loading Cassette
FCO type: Mandatory
Effective from S/N: All
Reason for change: The existing type of film carrier suffers from slipping between the
film roll and the film
carrier which causes a false end of film indication. The new type of film carrier has a
better grip on the film roll
which eliminates any slipping of the film roll.
17434
Punch Harness
FCO type: Conditional
Effective on machines with S/N lower than 11170
Reason for change: The connection between the Light harness and the Pneumatic &
Control system is different. The new connector will fit into the solonoid valve on the
Pneumatic & Control system.
17436
Punch Harness
FCO type: Conditional
Effective on machines with S/N lower than 11170
Reason for change: The connection between the Dark harness and the Pneumatic & Control
system is different. The new connector will fit into the solonoid valve on the Pneumatic
& Control system.
17480
Panel Assy comp level K to L
FCO type: Conditional
Effective on All S/N
Reason for change: Sometimes the panel starts up with Buzzer on and the plotter would not
start. sometimes the plotter will get stuck during booting.
17597
Fast DATA-II board comp level O to P
FCO type: Conditional
Effective on machines with S/N ? ?
Reason for change: Blank plots due to collision on the LBX bus between Fast DATA-II board
and CSS boards.
17847
Loading Cassette
FCO type: Conditional
FCO Kit P/N : 510F17847A - FCO Kit for Cass. Brd. Assy.
510F17847B - FCO Kit for Cass. Magnets
510F17847C - FCO Kit for F.C Addition
Effective for machines with S/N 11001 to 11070
Reason for change: To update Dolev 800 plotters Loading cassettes and Loading/Unloading
system assy to work with cassette NVM as required for S/W version 4.
17851
Punch Manifold
FCO type: Conditional
Effective on machines with S/N 11151 to 11155
Reason for change: Five plotters were shipped without the punch manifold system. In order
to install the punch system the manifold should be installed.
17998
OMC board comp level P to Q
FCO type: Conditional
Effective on all S/N
Reason for change: Implementation of the FCO will solve the "DAT - 12V" failures
(Integration/Data voltage).
Version 1.10 of the Dolev 800 diagnostic was released with
ECO 17929.
The effective release date is 11.7.93.
In this new version you will find some updates and additional features from version 1.08.
Detailed explanation of the diagnostics is described in Diag.
Doc. file.
All tests information are described in Diag. TST file.
Please print the two files and use them as a reference guide.
Note: While running the diagnostics, two tests fail:
Version 4.0 of the Dolev 800 was released with ECO 17495.
The effective release date was 6.7.93.
The plotters with S/N 11257 and higher will be shipped with system software 4.0.
Document no. 793-8F278 describes the software release.
Please note all the hardware updates that are needed for the new version.
5.1 In FCO 17766 the feeder sproket is replaced. The old
sprocket has 20 teeth and the new one has 18.
It is important to install the correct one whenever replacing the feeder motor (anyone of
the three). The feeder motor (DLV800- GEAR MOTOR DRIVE RIGHT/LEFT) in the spare parts kit
has the sprocket on it.
5.2 Six plotters were checked with software version 4.0 but were shipped with software version 3.2P. The S/N are 11250 to 11256. Please note that the strobe correction tables should be modified and see version 4.0 upgrade instruction. In general, the software will do the upgrade but the numbers will not be as the attached paper.
5.3 From plotter 11269 internal conveyor rails are installed inside the Dolev 800. In order to install the conveyor insert it in the plotter, lock it and adjust the funnel if needed.
5.4 From plotter S/N 11269, two belts were added to support the side doors.
5.5 A new serial number is assigned to the plotter. The new
number starts with the year (two digits). The second
two digits are the number of the week, the next 4 digits are the order number and the last
two digits are the production line identification.
Example: 9328029101
The year is 1993
The week is 28
The order number is 0291
The production line identification is 01
(opto-mechanical)
The NVM tables will continue with the old S/N. The change is from S/N 11286.
5.6 "Error in Data Transfer"
Sometimes, during plot, the message "Error in Data Transfer" appears. The same
ground must be connected to the Dolev 800 and to the I/O station (Whisper). It is
recommended to connect a ground cable between the Dolev 800 and the Whisper station. If an
Online processor is connected, it should have a separate ground and not the same one as
the Dolev 800. Make sure tht there is no ground connection between the Dolev 800 and the
processor.