Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
A. Posner
January 25, 1994
1. Overview
2. Recent FCO Topics
3. Recent ECO Topics
4. Service Items
5. Production News
This FSB summarizes the recent changes undertaken, the recent FCOs and service updates.
Adding cover to the lead screw edge.
FCO type = Conditional
Effectiveness: On all plotters with s/n lower than 9406XXXX
Reason for change: This FCO should be performed in order to prevent the dynamic optic cable from being caught by the lead screw or home position detector.
OMC board to comp. level R.
FCO type = Conditional
Effectiveness: On machines with s/n lower than 9401xxxx
Reason for change: This FCO solves problems of WCS RAM and failure of WCS loading in the OMC board.
The error: "OMC WCS load err" will also appear in the diagnostics.
ECO 18577
ECO 18603
ECO 18403
ECO
18746 - Spinner Drive PC Assy.
Change the Dolev 800 I/F to the PS from the fast data kit to "VLSI LBX + CLASS" kit.
The new kit, catalogue no. 510K37511A, consists of the following:
| Multimode fiber CBL 50/125 30 M | 138E00090 |
| SFLM board assembly | 503D27670 |
| Screen proc. LBX + CLASS SCREEN | 503D38691 |
| S/W, W/D PS/2 2-6.2/DLV800 V.4 | 510V37479 |
Effective as of 1 February, 1994. Please note date revision.
Change the 10 meter host cable to prevent the error message "Illegal Stop Spiral" during file exposure.
This change adds ground to the cable shield. As this cable is not part of a kit, an FCO is not required.
Update the C.R.I. board to enhance productivity. The new CRI board is newly designed and edited.
No change in functionality or compatibility level.
Effective as of 10 February, 1994.
Change the R30 connection from U4-3 and U4-1 to U3-4 and U3-. This change will prevent discharge between high and low voltages. No change in the board comp. level or functionality. The boards in the field were checked for discharge of voltages, and passed.
Effective as of 10 December, 1993
Film Guides (Cubics)
Diagnostics 1.1 Failings
The film guide assemblies have now been defined as such and can be ordered per the following:
| 507A38927 | Film Guide Right Assembly |
| 507A38928 | Film Guide Left Assembly |
| 507A38929 | Film Guide Assembly |
The film in/out detector - CreoScitex cat. no. 170O00040 - is used in the conveyor.
A new extender board has been defined and can be used as a jig. It's CreoScitex cat. no. is 503D27677.
OMC with comp. level R:
Fails on spinner check.
The Fail is on: OMC - Spinner - Spinner Counter and the messages are:
HS10 pin is low instead of high
Check C0_SPN25 singal in spinner xilinx
Strobe board with new design (no comp. level change):
Fails on Micro Contr. - ALU Instruct
The error message is:
Error found in ERROR buffer
Press <cr> to continue and the messages are:
ALU Status Bit (ALU_FO) error
ALU Status Bit (ALU ERR) error
ALU Status Bit (ALU_FIS) error
Spring and flat washers were added to the funnel lockers. These will help steady the funnel.
The out film selector's detector (on-line/cassette selector) requires checking in both on-line and cassette positions. The funnel will sometimes shift when ejecting and inserting the loading system.
The focus lens from machine 93490261 has pins which prevent the rotation of the lens while adjusting focus, thereby preventing a Bow problem while adjusting focus.
A conveyor has been assembled from machine 93490273 and the
funnel has been adjusted accordingly.
Please let us know if modification was required when the conveyor was installed in the
field.
Dolev 800 Serial Number
Starting from plotter number 93430424, the serial number in the NYVM table is 0 (serial
number 0). The machine s/n will appear on the NVM diskette and on all the documents
attached to the plotter.