Dolev 800 Field Service Diagnostics -
The Test Tree - Strobe 5
Xilinx
Correct Lut
Micro Contro
PLL
Low Range
High Range
Integration
Cassettes
Drivers
Spinner Drv
PWR Convert
Load
Verify
Card Ack
Clocks
Stop Spiral
Loads STROBE.XIL file from the current directory to Xilinx.
Compares Xilinx data to the file data. Uses the following
files:
STROBE.XIL, 2018MASK.XIL 3030MASK.XIL
Checks all STROBE5 Board Pc I/O address range (280H-2BBH
except 288H): When this test fails, all STROBE5 tests below do not execute in the batch.
Because this function is realized in the Xilinx,
Pass/Fail of the test depends on loading success.
Checks 20 Mhz clock and 8254 PIT:
Checks the STOP SPIRAL circuit by simulation:
Data Bus
Address Bus
Ramp
Random
Checks LUT RAM Data Bus.
Checks LUT RAM Address Bus for stacked or shorted bits.
Checks LUT RAM by writing Ramp (address = data).
Checks LUT RAM by writing Random data.
Overview
Seq Adrs Bus
Proms ChkSum
Seq Data Bus
Seq Instruct
ALU Data Bus
ALU Register
ALU Instruct
All tests below activate diagnostics programs from the PROM's.
Checks the Sequencer Address bus by single step:
*) Note that the Sequencer is not activated in this test.
Checks PROMs checksum:
Checks the Sequencer operation by single step:
Checks the Sequencer ability to perform commands from PROM's:
Checks the ALU Data Bus via YB(0-15) bus:
Checks ALU internal registers (single step):
Checks ALU logic and arithmetic operations:
i) Initialization steps for all PLL tests:
Normal
Lock Delay
Expose Delay
Checks PLL Low Range frequencies (45-130 MHz).
i) PLL tests Initialization.
Checks PLL Start of Line operation.
i) PLL tests Initialization.
Checks PLL Start of Line operation.
i) PLL tests Initialization:
Normal
Lock Delay
Expose
Delay
Checks PLL High Range frequencies (120-170 MHz).
i) PLL tests Initialization:
Checks PLL Start of Line operation:
i) PLL tests Initialization:
Checks PLL Start of Line operation:
i) PLL tests Initialization:
Overview
Omc - Strobe
Cri - Strobe
Power Suppl.
Data Voltage
Panel
Machine Exst
Com1<->Com2
Com3<->Com4
Checks Signals between Boards + External Devices.
Creates DATA EXPOSE, SWEEP ON pulses on STROBE5 and measure
them in OMC.
*) Note that there is blank region on the signal (without pulses), so the measuring has
been done for 5 times until the expected result has been received. If after 5 times the
result was not in the range, the last measuring has been displayed.
Creates STOP_SPRL~ and END_SSP~ signals by CRI and checks the response to the STP_SPRRL~ signal on the STROBE5.
Checks all DOLEV 800 power supplies through the OMC board: +5v -5.2v +15v -15v +12v.
Checks the voltages from DATA boards through the OMC board: +12v -12v +5v.
Checks Communication with panel and run panel Self Test Diagnostics.
Checks if the mechanics and optics (machine) is connected to the Standard Controller:
CPU Board Com1 <-> Com2 test via 504G34023 cable.
OMC Board Com3 <-> Com4 test via "Uknown yet" cable.
CASSETTE #1
CASSETTE #2
CASSETTE #3
Overview
Local Nvm
Destructive
Checks the CASSETTE #1
*) If Machine Exst test wasn't pass, then this test will not run in the batch
Checks the local NVM (EEPROM). one byte programming:
Program ramp from address 0 to ff.
Overview
Local Nvm
Destructive
Checks the CASSETTE #2
*) If Machine Exst test wasn't pass, then this test will not run in the batch
Checks the local NVM (EEPROM). one byte programming:
Program ramp from address 0 to ff.
Overview
Local Nvm
Destructive
Checks the CASSETTE #3
*) If Machine Exst test wasn't pass, then this test will not run in the batch
Checks the local NVM (EEPROM). one byte programming.
Program ramp from address 0 to ff.
RF Modulator
Relay Drv. 1
Relay Drv. 2
Stepper Drv.
Checks the Rf Driver:
Checks that each Relay can be Set and Reset in 100msec duration.
Checks that each Relay can be Set and Reset in 100msec duration.
Check the Stepper Driver clear signal:
Checks SIN_FDBK & COS_FDBK frequencies through the OMC for 9600 RPM.
Checks SIN_FDBK & COS_FDBK frequencies through the OMC for 12000 RPM.
Checks SIN_FDBK & COS_FDBK frequencies through the OMC for 13980 RPM.
Checks all functions of the driver exclude low power.
Checks all functions of the driver.
Failure will occur when the test runs with no machine.