Dolev 800 Field Service Diagnostics -
Utilities - Adjustments

Power Supply
H.P. Calib.
RF Driver
Cri PLL
Strobe5 VCO
Strobe5 Phase

Power Supply

All Pwr Sup
DVM + 5v
DVM - 5.2v
DVM +15v
DVM -15v
DVM +12v
Dat +12v
Dat -12v
Dat +5v

All Pwr Sup

Monitors all Dolev 800 power supplies through the OMC board: +5v -5.2v +15v -15v +12v Data+12v Data-12v Data+5v.

DVM + 5v

Monitors +5v on the Digital and Analog Display (DAD).

DVM - 5.2v

Monitors -5.2v on the DAD.

DVM +15v

Monitors +15v on the DAD.

DVM -15v

Monitors -15v on the DAD.

DVM +12v

Monitors +12v on the DAD.

Dat +12v

Monitors Data Unit +12v on the DAD.

Dat -12v

Monitors Data Unit -12v on the DAD.

Dat +5v

Monitors Data Unit +5v on the DAD.

H.P. Calib.

Home position detector adjustment utility:

  1. Bring carriage to Home position (fast motion).
  2. Read micro steps offset.
  3. Adjustment is ok for 125 < offset < 375.

*) Can be run in the loop.

RF Driver

RF Driver gain adjustment utility:

  1. Set modulator to value = 10V.
  2. Displays Rf Level Or Light Intensity.
  3. Displays Rf Level Graph for 0 to 4096 values (step 15).

Cri PLL

Cri Pll phase adjustment utility:

  1. Adjust P101 on CRI Board for getting 4.5V between U101-3 and GND.
  2. Connect Oscilloscope Ch1 to TS301-4.
  3. Connect Oscilloscope Ch2 to TS301-5.
  4. Adjust P102 on CRI Board for all frequencies 25ns < PHASE < 45ns.
  5. Manual frequency swap and verify phase and frequency.

Strobe5 VCO

Strobe VCO adjustment utility:

  1. Adjust L3 or L4 coil for High or Low frequency range.
  2. Connect Oscilloscope to PLL_OUT.
  3. Connect TP6 to GND.
  4. Connect TP7 (and OMC Diag Analog input) to external voltage supply (0-10 Volt).
  5. Verify that the PLL_OUT frequency is in range for 3 voltages inputs for both PLL ranges.

*) In future Measure DATA_EXPOSE clocks by OMC, multiply the result by 10 and display the result as PLL_OUT frequency.

Strobe5 Phase

Strobe Phase adjustment utility (for Low PLL range):

  1. Connect Oscilloscope Ch1 to TP1.
  2. Connect Oscilloscope Ch2 to TP2.
  3. Adjust P1 for 50-70 nsec between TP1 and TP2.

*) PLL is been locked for resolution 100 (low range).