Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Dolev 800 Field Service Diagnostics -
Utilities - OMC

Tools
Write/Read
Multimeter

Tools

Load XILINX
Load WCS
Reset 196
196 Ver Wcs
Send Opcode
Disable 196
Verify WCS

Load XILINX

Loads OMC.XIL file from the current directory to Xilinx.

Load WCS

Loads OMC.WCS file from the current directory to WCS RAM.

Reset 196

Creates RESET pulse on 196 for enable Micro running. StartUp test is been rerunning.

196 Ver Wcs

Micro (196) Compares WCS data to OMC.WCS file data.
Verify process is the same like from Pc, described before. This utility takes about 5 minutes, because of each reading from the WCS is been done by the opcode. Fail means that there was illegal writing to the WCS Code area, so after the fail WCS is being reloaded automatically and the next test execution might complete with Pass.

Send Opcode

User can send the specific opcode with proper parameters and receive returned values.

Disable 196

Disable Micro running. Enables PC control.

Verify WCS

OMC Micro (196) Loads user requested WCS file (not only OMC.WCS) and Compares WCS data to the file data during running of the micro. Verify process is the same like from Pc, described before. This utility takes about 5 minutes, because of each reading from the WCS is been done by the opcode. Fail means that there was illegal writing to the WCS Code area.
*) This Utility can run in loop.

Write/Read

Write PC->OMC
Read PC<-OMC
Write 196->OMC
Read 196<-OMC
Write PC->SPIN
Read PC<-SPIN
Write I2C DAC
Read I2C ADC

Write PC->OMC

Write by PC-CPU word/byte to the specific OMC memory address.

Read PC<-OMC

Read by PC-CPU word/byte from the specific OMC memory address.

Write 196->OMC

Write OMC-196 word/byte to the specific OMC memory address (opcode).

Read 196<-OMC

Read by OMC-196 word/byte from the specific OMC memory address (opcode).

Write PC->SPIN

Write PC-CPU byte to the specific OMC SPINNER memory address.

Read PC<-SPIN

Read by PC-CPU byte from the specific OMC SPINNER memory address.

Write I2C DAC

Write value to I2C Digital to Analog converter.

Read I2C ADC

Read the analog value from I2C Analog to Digital converter.

Multimeter

Volt Meter
Freq Meter

Volt Meter

Monitors any desired voltage through the OMC on DAD.

Freq Meter

Monitors any desired frequency through the OMC on DAD.