Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Dolev 800 Field Service Diagnostics -
Utilities - Optics

Modulator On
Modulator Off
Modul. Value
Modul. Graph
Shutter On
Shutter Off
Shutter Test
Laser Calib.
Laser On
Laser Off
Laser Beam
Laser/Mod Rpl

Modulator On

Turns the RF Modulator On.

Modulator Off

Turns the RF Modulator Off.

Modul. Value

Monitors the Laser Intensity value.

  1. Sets modulator to required value (0 - 10000).
  2. Turns the Shutter Off.

Modul. Graph

Displays Modulator Graph for 0 to 4096 values .

Shutter On

Sets shutter to upper position (On position), by supplying high power current to the shutter.

Shutter Off

Sets shutter to lower position (Off position), by supplying zero power current to the shutter.

Shutter Test

Checks and displays shutter rising and falling times. User can activate this utility in the loop.

Laser Calib.

Calibrates the Laser to the user desired value (2% accuracy). Returns the Modulator Value for which calibration was done.

Laser On

Turns Laser On via Relay Driver 2. Checks the feedback trough I2C.

Laser Off

Turns Laser Off via Relay Driver 2. Checks the feedback trough I2C.

Laser Beam

Turn Laser On , Modulator On (10000) , Shutter On.

Laser/Mod Rpl

Turn Laser On , Modulator On (10000) , Shutter Off.and monitors the Laser Intensity value.