Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Dolev 800 Field Service Diagnostics -
Utilities - Others
Overview
Conveyor
ND Filter
Punch-Real
Punch-Sim.
Checks other motors conveyor folter punch etc.
Conveyor On
Conveyor Off
Conv. Sol. On
Conv. Sol. Off
Turn Conveyor on.
Turn Conveyor off.
Turn Solenoid on.
Turn Solenoid on.
Filter CW
Filter CCW
Filter Stop
Turn Filter in Clock Wise (CW) direction.
Turn Filter in Counter Clock Wise (CCW) direction.
Stops the Filter.
Reset
Sequence
Go Forever
Unit In
Unit Out
Rod In
Rod Out
Slug Out On
Slug Out Off
Send Punch unit in must be between 1 to 5 sec .
Send Punch unit out must be between 1 to 5 sec .
Rod Punch is up.
Rod Punch is Down. ( Unit must be in ).
Slug is On. ( Unit must be in and Rod must be Down ).
Slug is On.
Unit In
Rod
Slug Out
Punch Seq
Detectors
Send Punch unit in.
Send Rod down.
Activates Jam out.
Activates punch sequence without checking detectors.
Monitors Detectors status and performs activate tasks for their change.