Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Accessing Utilities in Remote Mode for Dolev 800 versions 5.7 and 7.04

This option enables you to access various utilities.
Note: This mode supports several utilities which are not supported by the Control panel.

Access Remote mode on the workstation.

Using the Remote Mode
Util Mode: FUNCTIONS
Functions
Cassette NVM menu
Small Cassette form: FIELDS
Large Cassette
Operator Tables
Operations

Using the Remote Mode

Please refer to Remote Mode section in the release note.To access Tables or Service Utilities modes from the Host, select :
Set-Up: I/O Devices: Machine: Plotter Remote Mode.Use the <Arrow >, <Space>, and <Enter> keys to activate the interface.The Remote Mode enables you to activate the functionality of Util mode directly on the PS/2* Station.
After approximately 10 seconds, the Util Main screen appears.   

NVM Film Expose Functions UpdateCstNVM Exit

        

 

      Esc - Cancel    ^E - Quit

The underlined character in each word indicates the hot key (see Hot Keys below).

Util Mode: FUNCTIONS

NVM
Film
Set Loading
Load Media
Cut Media     NEW
Unload Media
Roller     NEW
Feeder     NEW
Conveyor     NEW
Mechanical Startup NEW
Load All Boards NEW
Detectors Status [informational only]    NEW
Expose
Intensity Strips form

NVM

NVM allows you to check the numbers and dates of software versions, exit to DOS, and activate NVM mode. After you select NVM from the Util Main screen (or press <N>), the NVM menu opens.

    About ..
    NVM         !

NVM menu

About . .     [informational only]
Select About from the NVM menu (or press <A>) to check the numbers and dates of software versions.

About
Utilities for Dolev 800                
Software Version: 

PC ==> 5.0.1 9-21-95
OMC ==> 5.0.1 9-21-95
CRI ==> 5.0.1 9-21-95
NVM ==> 5.0.1 9-21-95

Copyright (c) by CreoScitex Corp.

PC    ð    Specifies the number and date of the software version of the Control monitor interface.
OMC    ð    Specifies the number and date of the software version currently loaded in the OMC board.
CRI    ð    Specifies the number and date of the software version currently loaded in the CRI board.
NVM    ð    Specifies the date on which NVM tables were last loaded into the CRI.

NVM !           
Select NVM from the NVM menu to activate NVM mode.
The NVM Main screen appears. For further details, see NVM (mode) <F7> below.

Film

This option enables you to perform utilities related to the media (e.g., loading and unloading).

After you select Film from the Util Main screen (or press <I>), the Film menu is displayed.

Set Loading ..
Load Media ..
Cut Media         !
Unload Media         !
Roller ..
Feeder ..
Conveyor ..
Detectors Status     !
Mechanical Startup     !
Load All Boards         !

Film menu

Set Loading

Select Set Loading from the Film menu to automatically cut the section of the media that was exposed to light, and dispose of it in the unloading cassette/inline processor.

This option is identical to Set Loading in the Utilities menu of the Control panel (refer to the Dolev 800 User Guide, Media Management, Set Loading).
In the Set Loading form which appears:

Toggle the Cassette field to LRG, MED, or SML (the default), according to the size of cassette currently used. Note: If you are using two (2) Large cassettes, toggle the field to LWR (lower) or UPR (upper).

Load Media

Select Load Media from the Film menu to load film onto the Imagesetter. Place the supply cassette with the media in the load position, and close the supply cassette compartment door.
In the Load Media form which appears:

Toggle the Cassette field to LRG, MED, or SML (the default), according to the size of cassette currently used. Note: If you are using two (2) Large cassettes, toggle the field to LWR (lower) or UPR (upper).

In the Film Length field, enter the length of the film to be loaded into the Imagesetter (the default is 750.00 mm).

Cut Media   NEW

Select Cut Media from the Film menu to move the cutter from side to side (this is useful if film is not cut automatically)

Unload Media

Select Unload Media from the Film menu to unload media from the Imagesetter.
After you select Unload Media, the Service screen appears. The screen indicates the status of the OMC and CRI, the messages, and the active task. You may press <P> to display the Expose Parameters window (see Params <F3> above).

Roller     NEW

Select Roller from the Film menu to move the roller for testing purposes. In the Roller form which appears:
Toggle the To detector field to EP (end position - the default), HP (home position), or POS (the position specified in the To location field).

If you set the field to EP or HP, the value in the To location field is irrelevant.

Type in the To location field the position to which you wish to move the roller (the default value is 750.00 mm).

Feeder     NEW

Select Feeder from the Film menu to start/stop the movement of the loading axis.
In the Feeder form which appears:
Toggle the State field to Start or to Stop (the default).

If you set the field to Stop, the value in the Direction field is irrelevant.

Toggle the Direction field to Bkwd (backwards) or Frwd (forwards - the default).

Conveyor     NEW

Select Conveyor from the Film menu to start/stop the conveyor.

In the Conveyor form which appears:
Toggle the State field to Start (the default) or to Stop.

Mechanical Startup NEW

Select Mechanical Startup from the Film menu to perform mechanical tests and bring the machine to the Standby state (i.e., StartUp 7-11).

Load All Boards NEW

Select Load All Board from the Film menu to load the boards with software.

Detectors Status [informational only]    NEW

Select Detectors Status from the Film menu to find out the status of various detectors and parts.

The following window appears:

   

Detectors Status
Interlock Closed Yes Roller at Home Yes
Roller at End No
Upper door is Closed Yes
Lower door is Closed Yes Punch Unit Inside No
Upper lever is Closed Yes Punch Unit Outside Yes
Lower lever is Closed Yes Punch Rod Inside No
Small Cassette Det. Yes
Medium Cassette Det. Yes Output to Cassette No
Large Cassette Det. Yes Output to Processor Yes
Cutter at Right No Unload Cst Detector No
Cutter at Left Yes Processor is Ready Yes
Film In Det (Left) No Film In Conveyor No
Film In Det (Right) No Film Out Conveyor No

Detectors Status window   

Press <Enter> to continue.

Expose

This option enables you to perform utilities which calibrate the Imagesetter. After you select Expose from the Util Main screen (or press <X>), the Expose menu opens.

    Internal Pattern ..
Intensity Strips ..

Expose menu

Internal Pattern ..
Select Internal Pattern from the Expose menu to define parameters for a synthetic plot (generated by the Imagesetter). These films are used to check Imagesetter plotting accuracy prior to routine operation. After you select Internal Pattern, the Internal Pattern form appears.

Cassette ^ SML [SML]
Pattern ^ Grid [Grid]
Move Carriage ^ Yes [Yes]
Load Media ^ Yes [Yes]
Resolution 100 [100.00]
Spinner Speed 13800.0 [13800.00]
Write.Inten 3000 [3000]
Plot Height 100.00 [100.00]
Plot Width 700.00 [700.00]
Height Offset 0.00 [0.00]
Width Offset 0.00 [0.00]
Pattern Period 4 [4]
Pattern Size 50 [50]
Data Frequency 25.0 [25.00]
SSP number 0 [0]
Shutter Mode ^ Toggle [Toggle]

Internal Pattern form

Intensity Strips form

Intensity Strips form: FIELDS

Start Value [the range is 300 - 4000; the default is 1000]
Enter the value of the first intensity strip.

\End Value [the range is 1000 - 11000; the default is 5000]
Enter the value of the last intensity strip.

Step Inten [the range is 100 - 4000; the default is 500]
Enter the value of the gap between intensity strips.

Strip Height [the range is 10 - 1000; the default is 20]
Enter the height of the intensity strips (in mm).

Strip Width [the range is 0 - 1180; the default is 700]    NEW    
Enter the width of the intensity strips (in mm). Note: On the Control Panel, this value is set automatically by the system.

Cassette [toggle field; the default is SML]
Toggle to the size of cassette currently used.

Move Carriage [toggle field; the default is Yes]
Toggle this field to No for simulation mode, or to Yes for exposing mode.

Load Media [toggle field; the default is Yes]
Toggle this field to No for simulation mode (or in case film is already loaded), or to Yes to load film into the Imagesetter.

Resolution [the range is 30.00 - 200.00; the default is 100.00]
Enter the resolution (i.e., equal in height and width) in mm.

Spinner Speed [the range is 3000.00 - 14000.00;    NEW  the default is 13800.00]
Enter the speed of the spinner in RPM. Note: This resolution-dependent field affects the quality of the exposure.
On the Control Panel, this value is set automatically by the system.

Height Offset    [the range is 0.00 - 900.00; the default is 0.00]
Enter the distance in height between the origin of the Imagesetter and the start of the strips exposure.

Width Offset [the range is 0.00 - 1180.00; the default is 0.00]
Enter the distance in width between the origin of the Imagesetter and the start of the strips exposure.

Data Frequency [the default is 25.00]
Enter the frequency used to transfer the data (in the range 12.00 - 33.00).

SSP number [stop spiral; the default is 0 (none)]
Enter the number of lines after which the plotter performs stop spiral (in the range 0 - 500). For example: Entering 1 (one) performs stop spiral after every line; entering 500 performs stop spiral after every 500 lines.

Functions

This option enables you to perform various operations related to the parts of the Imagesetter.

After you select Functions from the Util Main screen (or press <F>), the following menu appears:

    Laser        >
Spinner ..
Carriage ..
Punch         >

Functions menu

For further details, refer to the documentation intended for the service engineer.

Cassette NVM menu

UpdateCstNVM

Use this option to set the number of cassettes to be used, and their parameters.

After you select UpdateCstNVM from the Util Main screen (or press <U>), the Cassette NVM menu appears.

Update CstMode ..
Small Cassette ..
Medium Cassette ..
Large Cassette .

Update CstMode    NEW
Use this option to indicate whether you wish to use one or two large cassettes.
After you select Update CasMode from the Cassette NVM menu, the Update CasMode form appears.

Toggle the Large Csts Mode field to 1 cst (the default) for one (1) large cassette (i.e., together with one small cassette and one medium cassette), or to 2 cst for two (2) large cassettes.

Small Cassette
Use this option to set the parameters of the small cassette. After you select Small Cassette from the Cassette NVM menu, the Small Cassette form appears.

Current length: 61 [61]
Material^: Film [Film]
Media Thickness^: 4 [4]
Media width: 304 [304]
Res/Int Table #^: 0 [0]
Full length: 61 [61]
Vendor^: None [None]

Small Cassette form

Small Cassette form: FIELDS

Current Length [the range is 0 - 61; the default is 61]
The default (61 m) specifies that the loaded film is a full roll. If you did not load a full roll of film, enter the current length (in meters).
This is the only field that updates during exposure.

Material [toggle field; the default is Film]
Toggle this field to Film (the default), Plate, or Paper, according to the media you loaded.

Media Thickness [the range is 4 - 7; the default is 4]
Toggle this field to 4 mil (the default) or to 7 mil, according to the media you loaded.

Media width [the range is 254 - 838; the default is 304]
Enter the width of the media you loaded.

Res/Int Table # [toggle field; default is 0]
Toggle this field to 0 (the default) to automatically select a Res/Int table to suit the vendor (i.e., if such is indicated in the Vendor field).
If the loaded film is not of the same type as the one previously loaded, toggle this field to the appropriate Res/Intensity table number.

Full length [the range is 0 - 63; the default is 61]
Enter the length of a full roll of film. Note: If you loaded a full roll of film, this value is identical to that of Current Length.

Vendor [toggle field; default is None]
Toggle this field to None (the default) in order to use the table specified in the Res/Int Table field.
Toggle this field to the name of the vendor of the loaded media to use the Res/Int table that is specified in the Res/Int Table # field. Note: If the Res/Int Table specifies 0, the system automatically selects a Res/Int table to suit the specified vendor.

Medium Cassette
Use this option to set the parameters of the medium cassette.
After you select Medium Cassette from the Cassette NVM menu, the Medium Cassette form appears. Note: Refer to the Small Cassette form above for all the parameters, except for Media width which is 508.

Large Cassette

Use this option to set the parameters for the large cassette.
After you select Large Cassette from the Cassette NVM menu, the large Cassette form appears. Note: Refer to the Small Cassette form above for all the parameters, except for Media width which is 838.

NVM (mode) <F7>
This option enables you to update, load, or save NVM and Grid tables.
Press <F7> (NVM) to activate NVM mode or select NVM from the NVM menu in Util mode.
After approximately 10 seconds, the NVM Main screen appears.

    Util    NVM(Dskt)    NVM(CRI)      Operations Exit

 

Esc - Cancel    ^E - Quit

NVM Main screen
NVM Mode: FUNCTIONS
Util

Select Util from the NVM Main screen (or press <U>) to display the Util menu.

About ..
Utilities !

Util menu
About..   
Select About from the NVM menu (or press <A>) to check the numbers and dates of software versions.

About
NVM Utilities                
Software Version:

PC ==> 5.0.1 6-15-94
NVM ==> 5.0.1 6-20-94

PC    ð    Specifies the number and date of the software version of the Control monitor interface.
NVM    ð    Specifies the number and date of the software version of NVM mode (i.e., of the TB.EXE file).

Utilities !   
Select Util from the Util menu (or press <U>) to activate Util mode. The Util Main screen appears (see Util (mode) <F6> above).

NVM(Dskt)
Select NVM(Dskt) from the NVM Main screen (or press <D>) to update the Operator, Service, and Factory tables which reside on the diskette (i.e., for backup purposes).

NVM(CRI)

Select NVM(CRI) from the NVM Main screen (or press <C>) to update the Operator, Service, and Factory tables which are loaded on the CRI board (i.e., used by the Imagesetter).
The NVM(Dskt) menu [or NVM(CRI) menu] appears.

    Operator Tables > Res/Int Tables >    1 ..
2 ..
.
.
10 ..
Service Tables >
Factory Tables >

NVM(Dskt) menu [or NVM(CRI) menu]

The Service Tables and Factory Tables options are intended for service engineers only. After you select one of these, the system prompts: Attention! This information is intended for Factory or Service use only!

Operator Tables

Select Operator Tables from the NVM(Dskt) menu (or from the NVM(CRI) menu) to update the values of a Res/Int table.
Select Res/Int Tables and the desired table (in the range 1 - 10).
The following form appears.

Material^: Film [Film]
Vendor^: None [None]
Media Thickness^: 4 [4]
Press <Enter> to continue

Modify the values for the active table, or press <Enter> to use the current values.

Material [toggle field; the default is Film]
Toggle this field to Film (the default), Plate, or Paper, according to the media you loaded

Vendor [toggle field; default is None]
Toggle this field to None (the default) in order to use the table specified in the Res/Int Table field.
Toggle this field to the name of the vendor of the loaded media to use the Res/Int table that is specified in the Res/Int Table # field. Note: If the Res/Int Table specifies 0, the system automatically selects a Res/Int table to suit the specified vendor.

Media Thickness [the default is 4]
Toggle this field to 4 mil (the default) or to 7 mil, according to the media you loaded.

After pressing <Enter> on the last field, the active Res/Int table appears.
1 .. Page 0

Resolution Inten. (12.5 Mhz) Inten. (25.0 Mhz)
40 [80] 1500 [1500] 3000 [3000]
50 [100] 1500 [1500] 3000 [3000]
60 [120] 1500 [1500] 3000 [3000]
70 [140] 1500 [1500] 3000 [3000]

Sample Res/Int table
Enter the intensity value for the relevant resolution and data frequency the active table, or press <Enter> to use the current values.
Refer to the Dolev 800 User Guide, Res-Intensity Calibration to determine the required intensity value.
After pressing <Enter> on the last field, the next page of the active Res/Int table appears (e.g., Page 1 of Table 1).
Note: To return to the previous page, press <Up Arrow>.

Operations

Select Operations from the NVM screen to handle NVM and Grid tables.
The Operations menu appears

   Save Tables to Nvm     !   
Save Tables to Dsk     !   
Load Grid to Nvm     !   
Default Info to Nvm    !   

   Operations menu

Save Tables to Nvm !   
Select this option to copy the current NVM tables from the diskette to the CRI board.

This is identical to Restore NVM from PC Diskette in the Save/Restore NVM menu on the Control Panel.

Save Tables to Dsk !   

Select this option to copy the NVM tables from the CRI board to the diskette.

This is identical to Save NVM on PC Diskette in the Save/Restore NVM menu on the Control Panel.

Load Grid to Nvm !   
Select this option to load the Grid tables from the diskette onto the CRI board.

This is identical to Load Grid from PC Diskette in the Save/Restore NVM menu on the Control Panel.

Default Info to Nvm !    NEW   
Select this option to reset the NVM tables on the CRI board using the system default values. Warning: In addition, selecting this option resets the grid tables.

This option is not supported on the Control Panel.


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.