Problem

  Exposure produces plate ablation. This ablation accumulates on the optic head lens protector, the light detector lens, and other components of the machine. Over time, this causes a noticeable decline in image quality, puts a strain on the laser diodes, and may ultimately cause diode failure.

Solution

  Install a Universal Debris Removal Cabinet (UDRC) kit (512-00107A) that vacuums the ablative particles from where they are produced—in front of the optic head. Installing this kit increases reliability and reduces the need to clean ablation from the internal components of the machine.

Time needed to implement

  Pre-installation site inspection: 30 minutes
Complete implementation: 5 hours

Prerequisite FCOs

 

Install the following:

Parts needed

 
Part name Quantity Part number
Universal Debris Removal Cabinet (UDRC) Kit
1
512-00107A
FCO Document
1
719-00210A

Procedure

 

Follow the Universal Debris Removal Cabinet (UDRC) Kit installation procedure for the BP configuration.

Logistics

  Approved quantities:
CSC
Quantity
CAM:
4
CEU:
4


Document number
  719-00210A-a
Technical contact(s)
  Mario Amir
Date submitted
  19 Feb 2004