Problem - Load Gripper does not reach the end position (EP)

Problem Description
The status of the detectors does not change after the Load Gripper is activated.

Cause

  1. Air pressure
  2. Detector or mechanical problem
  3. Drum position (enable detector)
  4. Local board

Solution

a. Air Pressure:

1.Verify that the air pressure dial indicator shows 6 atm.
2. Drain excess water from the air pressure unit.

b. Detector or Mechanical Problem:

1. Open the left and right load gripper EP detectors. (Hardware>Drum System>Gripper System) The detectors should be off.
2. Activate the load gripper manually by pushing the load gripper valve in the manifold and check:

c. Drum Position:
In order for the load grippers to be activated by the GUI, the load gripper enable detector should be ON.

  1. Bring the drum to load position:
    Others/Lotem 400 (right-click)
    Machine>Unload Head Gripper Location (mm)
  2. Open the load enable detector
    (Hardware>Drum System>Gripper System and make sure that the status changed to ON.
    If the status does not change, check for:

d. Local Board:
If none of the above steps helped, replace the local board.