Release date = 07 Nov 02
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Component |
Pressure/Vacuum unit assembly air pressure valve |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Problem |
The pressure/vacuum unit assembly includes a valve that has an additional air tube hole (referred to as an air pressure valve for future use in the FCO documentation). The hole is open, which creates a vacuum leak and causes intermittent plate pickup failure. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Solution |
Install a valve stopper (shown below) in the extra hole of the pressure/vacuum unit assembly valve.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Time needed to implement |
1/2 hour |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Prerequisite FCOs |
None |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Parts needed |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Special Tools needed |
3mm Allen key | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||