For version 1.18: select Start, and then select Run
to access the registry.
For version 2.0: refer to step 3-2.
In the Run window, regedit appears. Select OK.
Execute the following sequence:
For version 1.18: from the registry, select HKEY_LOCAL_MACHINE
Software
Scitex
Project
Lotem 800
I/O Object
Punch cards
Punch card
Punches.
For version 2.0: from Utilities menu, select Hardware
Lotem 800. Right-click on Lotem 800 and select I/O Object Punch cards Punch card Punches.
To define each punch motor installed, select relevant Punches
to Activate.
On the left side of the screen select the first punch
installed from the list of punches; on the right side of the screen opposite the selected
punch the word open appears.
Click open and in the Edit String window enter
1 in the Value Data field and then select OK.
To define the Punch offset, select Punch motor of the
first defined punch; press the right mouse button to bring up the Display Punch Motor
Parameters window.
Ensure that the Width Pos (mm) is 45 and that the Height
Pos (mm) is 500.
Select Save and then Send.
Repeat steps 5-9 for each installed punch to be defined.
To configure punch detectors:
Select detectors from the menu and repeat the same
procedure as described in configuring punches (above), for each installed punch detector.
Exit from the Lotem application to update the
database.
From the Hardware menu select Database and
then Punch to verify all punches installed are defined.
To define a punch system
configuration set:
From Punch menu select New, and then select
any combination of the previously defined punches (check each punch). These punches will
now comprise a Punch configuration set.
In the Name field type in the name you want for this
configuration of punches, and then select Save (typical name is the press name).
Exit from the application.
Activating Punch Configuration
System
To activate a configured punch system, open the Punch
System menu and select previously activated punch motors.
Similarly, select Detectors and select previously
activated detectors.
From the Punch System menu select Do Punch,
and verify that the Punch Detector Status for each activated punch changes from ON
to OFF.
Punch Configuration from the
Brisque
From the BrisqueLaunch pad, select Calibration.
On the Expose window, execute ConfigExpose. connected appears if there is connectivity between the
Brisque and the Lotem.
Select Press Format.
From Punch Configuration field, select the Punch
configuration set previously defined on PC Controller (it is also possible to select
all punch sets). For each Press Format, select a Punch Configuration Set and
then select OK.
From the Plate Expose dialog select Punch
System
Punch Params
Middle Center OK
Checking Punches
After all punches have been installed and configured, you
need to check the punches.
Load a plate using the automatic loading system.
Punch the plate and then remove it for visual comparison
with the master to confirm position of holes.
If necessary, move the punches.
Request the press operator to install plate on press to
verify position of punches.
To prevent registration problems, expose the four
separations and mount on press.