Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


”Carriage Motor Fine Detector Not Active“ error message appears after exposing an image


Product

 
  • Lotem® 800
  • Lotem 400
  • Lotem 400 Xpose
  • Lotem 200K
  • ThermoFlex® Mid
  • ThermoFlex Narrow

Error

 

Carriage Motor Fine Detector Not Active


Symptoms

 

After an image has been exposed, the carriage returns to home position and the Carriage Motor Fine Detector Not Active error message is generated.


Cause

 

The carriage can only be accurately positioned at home position, after it has completed the backlash movement.
The backlash movement is the distance the carriage must travel (in macro-steps) past the home position, in order to return to the accurate home position.
However, if the backlash movement is too far away from home position, the carriage will exceed the encoder range and the Carriage Motor Fine Detector Not Active error message will appear.


Solution

 

Reduce the distance between the backlash movement and home position.
Note: The distance between these two positions must remain greater than 2.7 mm.

Important: Before reducing the distance between these two points, make sure the carriage motor fine detector is adjusted correctly, then do the following:

  1. To reduce the carriage distance between the coarse and fine carriage detectors, make sure the parameters below are defined as follows:
    • MCF CARDS\MCF Card\CARRIAGE\Carriage Motor\ BackLash Correction (MM) = 4 ->3
    • MCF Card\CARRIAGE\Carriage Motor\Min Pos App Value
      = -4 -> -3

      Note: The above values may vary slightly between the different Lotem 800 configurations.
  2. Expose a plate and make sure of the following:
    • Carriage moves smoothly.
    • Carriage returns to home position without generating an error message.

See also

 

Adjusting the Carriage Motor Fine Detector on Lotem 800


Technical contact(s)
 

Yaron Shifman

Submitted by
 

Yaron Shifman

Date submitted
 

06 Feb 2005