Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Preventing banding on a Lotem 800V2 (FH)


Product

 

Lotem® 800V2 (FH)


Symptoms

 

Banding - very fine vertical lines, spaced approximately 0.5 mm apart, appear on exposed images.


Cause

 

The inner side of the protection glass, located in front of the detector, and the detector itself are both dirty.


Solution

 

Replace the light detector as described in the
FCO # 28131- Sealed Light Detector document.


See also

 

FCO # 28131- Sealed Light Detector


Technical contact(s)
 

Itai Peperovich

Submitted by
 

Itai Peperovich

Date submitted
 

14 Aug 2003


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.