Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


How to release a jammed plate from a punch on platesetters with Local2 boards

Plate double loading usually ends up with plates stuck in the punch(s) because the punch motor is not strong enough to complete its cycle of punching through the two plates.
On platesetters with Local2 boards there is a simple way to free the plates from the punches: Change the punch direction of rotation through the Registry; The punch easily rotates back to its previous home position and you can then pull the plate(s) out of the punch.
To change direction of punch rotation, change the value of the following parameter in the Registry:
Punch System/Punch Motor/Home Position Direction. Change the value from either 1 to 0, or from 0 to 1.
Note: This parameter does not exist in platesetters with Local3 boards.
(You don't have to change this parameter back to previous value since punching action is symmetrical- it does not matter which way the motor rotates).
This procedure is not applicable for platesetters with Local3 boards. To overcome this problem on platesetters with Local3 boards, a special punch direction inverter cable (part number 504L3525) has been designed. When the inverter cable is connected between punch and platesetter female connectors, it will change the motor rotation direction and enable the release of the plate as described above.


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.