Installing post code firmware for PC controller software version 3.70.02


Product

  Lotem™ Quantum Spectrum

Platform

 

PC

Operating system

 

Windows


Background

 

PC controller software works hand-in-hand with several firmware applications. This document provides instructions for installation of the post code firmware application that is compatible with PC controller 3.70.02.


Requirements

 

PC controller software version 3.70.02


Procedure

 
  1. Verify that PC controller software version 3.70.02 is installed.
  2. Shut down the Lotem application, as required.
  3. Close the Splot program, as required. This frees the serial port.
  4. Access the DOS prompt.
  5. At the DOS prompt, type C:\th2\tools\bload f=mcepost.bin i=post p=8. The post code firmware starts to load.
    Note: When the post code firmware has loaded successfully, the DOS prompt appears.

Test

 

After all firmware applications have been installed, you can verify successful installation by typing QUANTUM>>sw dir. A list of installed firmware applications will appear.


See also

 

PC controller software version 3.70.02 compatible firmware


Technical contact(s)
 

Nir Peleg
See the Escalation page for escalation contacts.