Background |
Plates, such as Spectratech, with untrimmed edges or poor emulsion coating, often have much lower focus sum readings at the home edge than in the center of the plate. The low sum often leads to edge detection and registration issues. To compensate, TH2 head firmware V1.03b and higher uses a lower surface reflectivity during edge detection than it uses during regular imaging. This lower reflectivity, edge sr, increases the focus beam output. This allows us to correctly locate the edge position, without affecting normal imaging. The procedure below outlines how to calculate and set edge sr for different types of media. |
||
|
|
|||
Procedure |
To calculate the edge sr value, complete the following steps: