Procedure
|
|
- Verify that PC controller software version 3.70.02 is installed.
Note: To verify the software version, from the PC Controller,
select Utilities>Machine Info. The software version
appears on the monitor.
- Verify that there is no media on the drum.
- Set the values for the following parameters as follows:
- Maximum Drum Vacuum Pressure Before Blanket Loading (mbar)
= -350
- Minimum Drum Vacuum Pressure Before Blanket Loading (mbar)
= -130
Note: To access the
parameter, do the following:
- From the PC Controller, select Utilities>Hardware.
- In the Hardware tree, double-click Loading
System, and then right-click Loading System.
- In the Properties dialog box, double-click
Load Blanket and locate the relevant parameter.
- Access the Drum Vacuum Analog Detector dialog box.
Note: To access the Drum Vacuum Analog Detector dialog
box, do the following:
- From the PC Controller, select Utilities>Hardware.
- In the Hardware tree, double-click Drum System>Drum
Detectors>Drum Vacuum Analog Detector. The Drum Vacuum
Analog Detector dialog box appears.
- Activate the drum vacuum pump and allow it to operate for approximately
15–20 seconds.
Note: To activate the drum vacuum pump, do the following:
- From the PC Controller, select Utilities>Hardware.
- In the Hardware tree, double-click Drum System>Drum
Solenoids>Drum Vacuum Pump.
- In the Drum Vacuum Pump dialog box, click Start.
The drum vacuum pump is activated.
- Check the vacuum level in the Drum Vacuum Analog Detector dialog box
and, when the vacuum level has stabilized, verify that it is between
-350 and -130. If the level is:
- Higher: The drum vacuum holes are clogged. Clean the holes as
described in Periodic Maintenance.
- Lower: There may be a leak in the vacuum system, or the filter
may need to be replaced.
Note: Verify the value for the Drum Vacuum Pressure
Valve Before Blanket Loading parameter, and write it down. For this
procedure, we will refer to this value as Y.
- Deactivate the drum vacuum pump by clicking Stop
in the Drum Vacuum Pump dialog box and then load an 8up carrier.
- Open the rear door and verify that the carrier
is properly attached to the drum. Pay close attention to:
- The area near the drum pin
- The area around the vacuum grooves
Note: If the “drum vacuum pump is not in the allowed range”
error message appears in the PC controller, ignore it and continue the
procedure.
- In the Drum Vacuum Analog Detector dialog box,
verify the current value for the drum vacuum analog
detector, and write it down. For this procedure, we will refer to this
value as X.
- Subtract Y from X. For this procedure, we will refer
to the difference as Z1 (X-Y=Z1).
- Access the Drum Vacuum Difference for 8up Blanket parameter.
Note: For example, if X=-320, and Y=-265, then the numerical
value for Z1is -55.
(-320)-(-265)=-55
The value should be a negative number.
- Leave the carrier on the drum and load an 8up receiver.
Note: Use a cheater, as required.
- Perform steps 9 and 10, but this time, we will
refer to the difference as Z2.
- Access the Drum Vacuum Difference for 8up Receiver parameter
and enter Z2's numberical value.
Note: For example, if X=-720, and Y=-265, then the numerical
value for Z2 is -455. That is, (-720)-(-265)=-455.
The value should be a negative number.
- Leave the carrier and receiver on the drum and load an 8up donor.
- Perform steps 9 and 10, but this time, we will
refer to the difference as Z3.
- Access the Drum Vacuum Difference for 8up Donor parameter
and enter Z3's numberical value.
Note: For example, if X=-720, and Y=-265, then the numerical
value for Z3 is -455. That is, (-720)-(-265)=-455.
The value should be a negative number.
- Unload the donor and the receiver, and then load a 4up receiver.
- Perform steps 9 and 10, but this time, we will
refer to the difference as Z4.
- Access the Drum Vacuum Difference for 4up Receiver parameter
and enter Z4's numberical value.
Note: For example, if X=-720, and Y=-265, then the numerical
value for Z4 is -455 (-720)-(-265)=-455.
The value should be a negative number.
- Leave the 4up receiver on the drum and load a 4up donor.
- Perform steps 9 and 10, but this time, we will
refer to the difference as Z5.
- Access the Drum Vacuum Difference for 4up donor parameter and
enter Z5's numerical value.
Note: For example, if X=-720, and Y=-265, then the numerical
value for Z5 is -455 (-720)-(-265)=-455.
The value should be a negative number.
|