Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


“The debris removal timeout failed” error message appears when a plate is being exposed


Product

 
  • Lotem® 800
  • Lotem 800II
  • Lotem 800 Quantum
  • Lotem Quantum Spectrum

Error

 
  • The debris removal timeout failed
  • The task debris removal on switch failed

Symptoms

 

When exposing a plate, one or both of the above error messages appears.

 


Cause

 

The Value of the Max. Allowed Valve Activation Time(DWORD) [Sec] parameter is set too low and causes the UDRC to time out.


Solution

 
  • From within Regedit, locate:
    Lotem800V\IO OBJECTS\LOCAL 3\VALVE\Debris Removal\Max. Allowed Valve Activation Time(DWORD) [Sec]:



  • Amend the existing value (7200) to a number high enough to prevent the UDRC from timing out, for example, 65535

 


See also

 

“The task debris removal on switch failed” error message appears when running Lotem Controller 3.75.09.


Technical contact(s)
 

Nir Peleg

Submitted by
 

Nir Peleg

Date submitted
 

05 Jul 2004