Preventing QuantumSeries/Firmware problems when using Service Shell 2.3 on Microsoft Windows 95


Product

 
  • Lotem® 800 Quantum
  • Lotem 800 II
  • Lotem Quantum Spectrum
  • Lotem 400 Quantum
  • Service Shell 2.3/Microsoft® Windows® 95

Symptoms

 

When using Service Shell 2.3 on Windows 95, the firmware upgrade kit and/or QuantumSeries.spt script fail to run.


Cause

 

MCE firmware versions 1.20 and earlier, are only compatible with QuantumSeries scripts versions 0.09 and earlier.


Solution

 
  • If using MCE firmware 1.20 and earlier, make sure that the QuantumSeries script is version 0.09 or earlier.
  • Download the relevant firmware upgrade file.
    Extract the file and replace the existing QuantumSeries.spt file, located in the Device folder: c:\ServiceShell\scripts\device\.

Technical contact(s)
 

Nir Peleg

Submitted by
 

Nir Peleg

Date submitted
 

25 Oct 2004