Component |
Carriage-beam holding pin |
||
Symptoms |
The start line of some of the jobs shifts around the drum approximately 100 microns towards the gripper. This happens mainly at the end of the plate (near 80-95%). The shift is anywhere between a few millimeters and 0.5 millimeters wide, and the exposure lines shift down by a few millimeters. When this happens, one swath shifts, followed by one that does not. A hairline-thin black line appears on the border of every shift, indicating a carriage jump of approximately 10 microns, as shown in the example below.
|
||
Cause |
The carriage-beam holding pin slides backwards, leaving the end of the carriage to hang trembling in mid-air. |
||
Solution |
Pull the pin back to its proper location, as described in the following procedure:
|
||