Machines affected |
|
||
Error |
|
||
Symptoms |
During a new installation focus learn fails. System error 03529 may be displayed. | ||
Cause |
During a new installation focus learn fails. If the 3-phase power is not connected correctly, an incorrect sequence in the 3-phase power causes the drum's vacuum pump to blow air out instead of suck air in. This causes incorrect loading of the plate (for example, bubbles in different places) and the corresponding focus learn problems. |
||
Solution |
Manually check the vacuum holes in the drum to ensure the vacuum pump is working properly. Note: In the past, noise generated by the vacuum pump would indicate this problem, but not anymore. The new vacuum pumps do not make this noise so you must manually check the orifices. |
||
See also |
|||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
04 Aug 2004 |
||