Troubleshooting focus learn failures on a new installation


Machines affected

 
  • Lotem Quantum
  • Lotem Quantum Spectrum
  • Lotem 800 II

Error

 

SYS> 03529 Failure of the focus learn


Symptoms

  During a new installation focus learn fails. System error 03529 may be displayed.

Cause

 

During a new installation focus learn fails. If the 3-phase power is not connected correctly, an incorrect sequence in the 3-phase power causes the drum's vacuum pump to blow air out instead of suck air in. This causes incorrect loading of the plate (for example, bubbles in different places) and the corresponding focus learn problems.


Solution

 

Manually check the vacuum holes in the drum to ensure the vacuum pump is working properly.

Note: In the past, noise generated by the vacuum pump would indicate this problem, but not anymore. The new vacuum pumps do not make this noise so you must manually check the orifices.


See also

 

Technical contact(s)
 

???

Submitted by
 

Alvaro Ireta

Date submitted
 

04 Aug 2004