Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Resolving low XY and proof bar vacuum levels


Product

 
  • Lotem® Quantum Spectrum
  • Lotem 800 Quantum
  • Lotem 800

  • Component

     

    XY vacuum pump - Becker DT 4.8.


    Symptoms

     
    • Plate loading intermittently fails and the Vaccum did not grab plate error message is displayed.
    • Spectrum loading system intermittently fails.
    • Problems when loading proof media.

    Cause

     

    Low XY and proof bar vacuum levels are caused by a blocked filter (p/n 342A10070).


    Solution

     

    As part of the biannual preventive maintenance, check and replace (if required), the XY vacuum pump filter - as described in the Lotem 800 Q/II Family Planned Maintenance Checklist.

    Note: The procedure for replacing the pump filter can be found in the Maintenance sections of TechPlanet.


    Technical contact(s)
     

    Itai Peperovich

    Submitted by
     

    Itai Peperovich

    Date submitted
     

    27 Jan 2004


        Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.