Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
| ||
Component |
XY vacuum pump - Becker DT 4.8. |
||
Symptoms |
|
||
Cause |
Low XY and proof bar vacuum levels are caused by a blocked filter (p/n 342A10070). |
||
Solution |
As part of the biannual preventive maintenance, check and replace (if required), the XY vacuum pump filter - as described in the Lotem 800 Q/II Family Planned Maintenance Checklist. Note: The procedure for replacing the pump filter can be found in the Maintenance sections of TechPlanet. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
27 Jan 2004 |
||