Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Field Change Order 512-00304A: Adapt ThermoFlex Mid II to cTUVus regulations


Applies to

 

Thermoflex® Mid II

Priority = For six specific customers only, check before ordering.
Release date = 11 Sep 2005

Problem

 

The platesetter has not been adapted to cTUVus regulations.

Solution

 

Install the relevant parts and add the relevant safety labels as described following.

Note: The new drum slow motor contains a fuse that protects the motor.

Parts needed

 
Part number Description
Quantity
Comments
500-02671A D-box
1
 
382-01210A L-box warning label
3
1 spare
182-00029 E-box fuses
6
4 spare
382-01146A E-box warning label for fuses
 
 
382-01209A Standby position labels
3
1 spare
220-00925A Drum slow motor
1
 

 

220-00925A includes:

  • 252-02388A: Pulley 18 x 15 - rework
  • 385T71181: Roll pin STST 1/8 x *3/4"
  • 1
  • 2
1 spare roll pin
719-00549A FCO document
1
 

 

Procedure

 
  1. Install the following parts. Links to procedures are provided where relevant.
  2. Stick the warning labels onto the machine as shown following.
    • PN 382-01210A—stick two labels on the top of the L-box.

    • 382-01146A—stick one label on the E-box



    • 382-01209A—stick two labels on the back panel.



Technical contact
 

Viki Arviv

Date submitted
 

11 Sep 2005

   
Doc no. 719-00549A Rev. B