Background
|
|
The objective of the elevation calibration test is to find the correct
elevation angle of the optical head. When the elevation angle is correct,
all 24 or 48 beams are in focus. Incorrect elevation results in a different
optimal focus value for beams on each side of the V groove.
Elevation does not depend on plate type, size or thickness. The test
and adjustment (if required) can be performed on any plate that the customer
uses.
|
Procedure
|
|
Expose two
focus tests on the same plate. The first focus test uses only the first
five beams while the second test uses only the last five beams. If the
elevation angle is correct, the optimal focus value will be the same (+/-
a 10 micron tolerance) for both tests.
This procedure contains two stages:
Testing elevation
First test:
- Perform the focus test on only the first five and last five diodes
with th following changes:
- In Test Focus Values (Steps):
Fromtype the optimal focus value that you found in
the focus test -30.
Totype the optimal focus value that you found in the
focus test +30.
- Use 7 steps.
- Use the following intensity values:
- 660 mV diode/flexo plate: 300 mV
- 1 W diode/flexo plate: 500 mV
- 1 W diode/offset plate: 120 mV
- In ThermoFlex Controller, select the laser group to test:
- Select Utilities>Hardware>Expose System>Laser System
and right-click Laser Group.
- In the Properties: Laser Group dialog box, change the value of the
Last Expose Laser Active parameter to 4.
Only the first five beams will be tested.
Note: Make sure that the nozzle is as far as possible from the drum.
- Expose the test file.
Second test
- In ThermoFlex Controller, change the laser group to test:
- Select Utilities>Hardware>Expose System>Laser System
and right-click Laser Group.
- In the Properties: Laser Group dialog box, make the following changes:
- Last Expose Laser Active23 (or 47, as required).
- First Expose Laser Active19 (or 43, as required).
Only the last five beams will be tested.
- In the Offset box, type an offset value around the drum so
that the batch of strips in the second test are exposed below the batch
of strips in the first test.
Note: Make sure that the nozzle is as far as possible from the drum.
- Expose the test file.
To determine whether the elevation angle of the optical head is correct,
examine the results of the two sets of exposed strips and determine
the best focus value for each set.
- If the two best focus values are equal or less than ten microns
apart, the elevation angle is correct.
- If the two best focus values are more than ten microns apart, proceed
to adjusting elevation.
Adjusting elevation
Note: The numbers in brackets identify the parts shown in the
diagram in the Image section.
- Remove the focus limit block from the carriage.
- Connect the elevation jig [3] to the optical head.
This will help support the lens and help with initial adjustment of
the head.
- Connect the fine dial gauge[4] to the elevation jig.
Note: Before proceeding, write down the value on the
fine dial gauge [4].
- Carefully loosen the three screws [2] that secure the optical head
until the friction is strong enough to hold the optical head but still
enable its adjustment.
Note: Be careful that the lens tube does not drop completely.
- Calculate the value (C) to move the telescope tube, using the best
focus values for the groups of 5 diodes that you measured in steps 2
(B) and 7 (A) of the Testing elevation section,
for example:
- ADiodes 43-47 (or 19-23) = 135
- BDiodes 0-4 (see step 2 in the testing elevation section
) = 95
Subtract A from B and divide by 2: (B-A)/2=C
- Calculate the direction of the telescope tube adjustment according
to the results you received in step 5:
- A>Blower the back of the telescope tube by C microns.
- A<Braise the back of the telescope tube by C microns.
- To change the elevation angle of the optical head, rotate the pin
[1] and move the optical head. Watch the dial indicator as you move
the optical head.
For example, if the focus value for B is 95 microns and the focus value
for A is 135 microns, move the optical head 0.2 mm upward.
- Tighten the three screws that secure the optical head.
|