Artifacts Appear on the Image Intermittently on ThermoFlex Mid and Narrow Devices


Product

 
  • Kodak® ThermoFlex® Narrow
  • ThermoFlex Mid II
  • ThermoFlex Mid

Symptoms

 

Artifacts appear on the image. This occurs intermittently.


Cause

 
  • Electromagnetic induction occurs between the TSP cable and the transformer.
  • One of the following components needs to be cleaned:
    • Leadscrew
    • Lens
    • Nozzle

Solution

 
  1. Move the TSP cable farther away from the external transformer to prevent electromagnetic induction.
  2. Clean the following components, as described in Detailed Maintenance Procedure:
    • Leadscrew
    • Lens
    • Nozzle