Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Top Right Screw on Carriage Spacer Collides with Platesetter Mainframe on ThermoFlex Mid and Narrow


Product

 
  • ThermoFlex® Mid
  • ThermoFlex Narrow

Symptoms

 

When adjusting the focus range for thick plates, the top right screw on the spring jam (spacer) collides with the platesetter mainframe.


Cause

 

The top right screw on the spacer sticks out too far and collides with the platesetter mainframe when the optic lens assembly ("telescope") moves away from the drum.


Solution

 

To prevent this collision, replace the two 3 mm inside spacers with 4 mm spacers (252-07059A), and replace the right front spacer with a 3 mm spacer (252-07060A) that has a deeper indentation hole for the top screw, as described in the Achieving a Focus Range for Plates with a Thickness of 0.7 to 3.2 mm procedure.


Technical contact(s)
 

Viki Arviv

Date submitted
 

13 Apr 2005


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.