Background |
In order to achieve the proper focus range for relatively thick plates, the optic lens assembly ("telescope") must move away from the drum. When the carriage moves, the top right screw on the spring jam (spacer) may collide with the machine chassis. Replacing the spacers, described following, ensures that the screw on the spacer does not hit the chassis when the carriage moves to HP or EP. |
||
Requirements |
|
||
Procedure |
To prevent this collision, replace the two
3 mm inside spring jams (spacers) with 4 mm spacers (252-07059A), and
replace the right front spacer with a 3 mm spacer (252-07060A) that has
a deeper indentation hole for the top screw, as follows:
|
||
Technical contact(s) |
Content owner: Viki Arviv |
||
Date submitted |
14 Nov 2004 |
||