Laser diode failure on Magnus 400


Product

 
  • Kodak® Magnus™ 400
  • Magnus 400 E

Component

 

Laser diode


Cause

 

Laser diode failure


Solution

 
  1. Run diagnostics. If the LDA driver board passes the diagnostic tests, you do not need to replace the LDA driver board.
  2. If one or more diode failures occur, in the Magnus 400 Controller, select Utilities > Hardware > Expose System, and double-click Laser Group.
  3. In the Laser Group dialog box, in the Lasers Calibration Area, click Auto Cal to calibrate the diodes.



  4. If the problem persists, see Splice the problematic diode.

Technical contact(s)
 

Alon Davidor

Submitted by
 

Alon Davidor

Date submitted
 

04 May 2008


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.